Version ESX 4.0.0, 236512
Storage iSCSI
Initiator Software
A LUN that was presented to my ESX host was deleted on the san without removing it from the host and now I’m getting failover errors in the vmkernel.
Mar 30 06:49:40 bl480g1-03 vmkernel: 20:09:00:10.348 cpu1:4222)WARNING: NMP: nmp_DeviceAttemptFailover: Logical device "naa.6090a01820dc7c5f9b97a440089a3483": awaiting fast path state update...
Mar 30 06:49:41 bl480g1-03 vmkernel: 20:09:00:11.348 cpu1:4222)WARNING: NMP: nmp_DeviceAttemptFailover: Retry world failover device "naa.6090a01820dc7c5f9b97a440089a3483" - issuing command 0x4100030b07c0
Mar 30 06:49:41 bl480g1-03 vmkernel: 20:09:00:11.348 cpu1:4222)WARNING: NMP: nmp_DeviceAttemptFailover: Retry world failover device "naa.6090a01820dc7c5f9b97a440089a3483" - failed to issue command due to Not found (APD), try again...
Mar 30 06:49:41 bl480g1-03 vmkernel: 20:09:00:11.348 cpu1:4222)WARNING: NMP: nmp_DeviceAttemptFailover: Logical device "naa.6090a01820dc7c5f9b97a440089a3483": awaiting fast path state update...
Mar 30 06:49:42 bl480g1-03 vmkernel: 20:09:00:12.347 cpu6:4222)WARNING: NMP: nmp_DeviceAttemptFailover: Retry world failover device "naa.6090a01820dc7c5f9b97a440089a3483" - issuing command 0x4100030b07c0
Mar 30 06:49:42 bl480g1-03 vmkernel: 20:09:00:12.347 cpu6:4222)WARNING: NMP: nmp_DeviceAttemptFailover: Retry world failover device "naa.6090a01820dc7c5f9b97a440089a3483" - failed to issue command due to Not found (APD), try again...
With esxcfg-mpath both paths are showing dead.
How do I remove these dead paths?